Sensors × Modulario

Connect temperature, humidity, pressure, and weight sensors to Modulario ERP via an IoT gateway. Monitor conditions in your warehouse, production facility, or cold chain — alerts, logs, and HACCP reports directly in the system.

Sensors

Hardware

M

Modulario

ERP + CRM platform

Via Zapier/Make

What the integration actually solves

Temperature and humidity monitoring in the warehouse

Wireless sensors (SHT, DHT-22, Ruuvi Tag) transmit readings via an MQTT gateway to Modulario every 5 minutes. When the permitted range is exceeded (e.g., cold storage +2 °C to +8 °C), the system immediately alerts the responsible person.

Production quality control and SPC

Sensors on machines record temperature, pressure, and vibration in real time. Modulario production evaluates deviations from norms, logs them to the production order, and raises a service request when a limit is exceeded.

Automatic HACCP records for food industry

For operations subject to HACCP legislation, Modulario automatically archives temperature records with timestamps and device identification. An audit export is available at a single click — no manual log sheets required.

Connect in minutes

  1. 1
    Install sensors and verify they communicate via MQTT, Modbus RTU/TCP, or HTTP REST.
  2. 2
    In Modulario, go to Settings → Integrations → IoT/Sensors and add a new IoT gateway.
  3. 3
    Enter the MQTT broker address (or Modbus IP/COM) and authentication credentials.
  4. 4
    Create measurement points — assign topics or registers to warehouse locations, production workstations, or equipment.
  5. 5
    Set alarm thresholds and notification rules (email, SMS, push notification in the app).

Frequently asked questions

What communication protocols are supported?

MQTT (v3.1.1 and v5), Modbus RTU, Modbus TCP, OPC-UA, HTTP REST webhooks. For proprietary protocols, a generic CSV import via FTP is available.

What is the measurement recording frequency?

Configurable from 1 second to 1 hour. For HACCP, a 15-minute interval is sufficient; for production SPC control, we recommend a 10-second interval.

How long is sensor data retained?

Raw data is retained for 2 years, aggregated hourly values for 5 years. For HACCP, archival can be configured to meet regulatory requirements.